loading

Professional manufacturer of electronic analytical balance and laboratory instruments in China.

FA Series Analytical Balance for Laboratory Weighing and Measurement 1
FA Series Analytical Balance for Laboratory Weighing and Measurement 2
FA Series Analytical Balance for Laboratory Weighing and Measurement 3
FA Series Analytical Balance for Laboratory Weighing and Measurement 4
FA Series Analytical Balance for Laboratory Weighing and Measurement 5
FA Series Analytical Balance for Laboratory Weighing and Measurement 1
FA Series Analytical Balance for Laboratory Weighing and Measurement 2
FA Series Analytical Balance for Laboratory Weighing and Measurement 3
FA Series Analytical Balance for Laboratory Weighing and Measurement 4
FA Series Analytical Balance for Laboratory Weighing and Measurement 5

FA Series Analytical Balance for Laboratory Weighing and Measurement

FA series analytical balance

The FA series analytical balance delivers reliable high-resolution weighing for laboratories and production environments that require precise milligram and sub-milligram measurements. Engineered for fast stabilization, excellent repeatability and minimal drift, the FA series features a protective draft shield, user-friendly interface, configurable weighing modes (net, percent, density, counting) and secure data output for GLP/GMP traceability via USB/RS232. Optional internal calibration and robust connectivity make it easy to integrate with LIMS or QC systems for automated workflows.

Usage scenarios (3 sentences):

- In pharmaceutical R&D and QC, the FA series is used for accurately measuring active ingredients, preparing reference standards and documenting batch weights to meet regulatory traceability.

- In chemical, food and environmental testing labs it supports precise sample prep, moisture-related formulations and density determinations where repeatable small-mass measurements are critical.

- In manufacturing and education, it speeds up incoming inspection, piece counting and teaching labs that require dependable, easy-to-use analytical weighing.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Precise Measurements, Durable Design 

    The FA series analytical balance delivers laboratory-grade precision and repeatable results, enabling fast, confidence-inspiring mass measurements for demanding research and quality-control workflows. Secure, recyclable packaging and a compact, ergonomic chassis with a low-profile draft shield and intuitive touchscreen combine high-quality materials and refined styling to protect the instrument, simplify setup, and make operation effortless. Backed by responsive technical support and optional on-site calibration, the FA series minimizes downtime, ensures traceability, and keeps your lab compliant and productive.

    ● Ultra Precise Repeatable Weighing

    ● Fast Stabilization With Outputs

    ● Compact Rugged Stainless Steel

    ● Factory Calibrated Service Warranty

    carousel-2

    Product Display

    carousel-2
    carousel-2
    Read More
    carousel-5
    carousel-5
    Read More
    carousel-7
    carousel-7
    Read More

    Accurate, Stable, Fast, Intuitive

    carousel-3
    Laboratory Grade Weighing Stability
    Precision engineering and strict quality control give the FA series the stability required for microgram-level accuracy and consistent repeatability. Long-term performance is maintained through low drift and environmental compensation, ensuring reliable results in demanding laboratory settings.
    未标题-2 (16)
    High Resolution Sensor Accuracy
    High-resolution sensors, a draft-shield enclosure, and fast response times deliver sensitive, dependable measurements across research and QC workflows. The design minimizes air currents and noise, reducing measurement variability and shortening stabilization time.
    未标题-3 (10)
    Intuitive Touchscreen Workflow Flexibility
    The responsive touchscreen and multiple weighing modes make operation straightforward and adaptable to a wide range of laboratory tasks. Customizable workflows and user profiles speed training, reduce operator errors, and improve overall throughput.
    未标题-4 (5)
    Seamless Calibration Data Connectivity
    Simple calibration procedures, USB/RS232 outputs, and user-friendly software enable easy data transfer and traceable record-keeping for compliance. The stainless-steel pan and integrated connectivity minimize downtime and simplify integration with LIMS and audit processes.

    Core attributes:

    The FA series analytical balance delivers high-precision weighing with microgram-level readability, a generous capacity range, rapid stabilization and built-in calibration options to ensure consistent accuracy. It adds practical value through excellent repeatability, multiple weighing modes (counting, percent, density), and standard data interfaces for seamless data transfer and laboratory integration. The instrument’s compact, rigid housing, anti-vibration base and transparent multi-panel draft shield with an easy-clean pan combine to protect measurements and simplify operation and maintenance.

    ◎ 

    ◎ 

    ◎ 

    carousel-6

    Application Scenario

    application scenario 1
    In pharmaceutical formulation and quality applications, the FA series analytical balance delivers sub‑milligram accuracy for precise dosing and formulation development, ensuring each ingredient is measured reliably during R&D and production. Its repeatable measurements and traceable output support batch quality checks and regulatory compliance for consistent drug quality.
    application scenario 2
    For analytical research and development, the FA series enables accurate sample preparation, titration, and reagent weighing essential to chemical and biotech projects. High sensitivity and stable performance reduce sample loss and improve reproducibility across experimental runs.
    carousel-5
    application scenario 3
    In educational teaching and training settings, the FA series streamlines hands‑on weighing exercises and calibration practice while offering straightforward data logging for instructor review. Its user‑friendly interface and robust design make it ideal for demonstrating best practices and building student proficiency.
    carousel-7
    application scenario 4
    In industrial quality control and compliance, the FA series facilitates routine QC assays, incoming material checks, and creates traceable documentation required for manufacturing audits. Reliable performance and clear recordkeeping help ensure products meet specifications and support timely batch release.

    Material Introduction

    The FA series analytical balance uses a polished stainless-steel weighing pan for excellent corrosion resistance and easy cleaning. A tempered, anti-static glass draft shield encloses the weighing chamber to protect samples from air currents while maintaining clear visibility. The instrument combines a die-cast aluminum chassis with an ABS outer housing and a precision load cell to deliver rigid support and long-term measurement stability.


    ◎ Stainless Steel Pan 

    ◎ Anti-Static Enclosure

    ◎ Durable Internal Alloys

    carousel-6

    FAQ

    1
    What is the FA series analytical balance and what are its common application scenarios?
    The FA series analytical balance is a high-precision laboratory balance designed for measurements with readability commonly in the 0.1 mg to 0.01 mg range (check the model specs). It is used where high accuracy and repeatability are required. Common application scenarios include: analytical and research laboratories, pharmaceutical formulation and QC, chemical analysis, environmental testing, micro-weighing of reagents, quality control in electronics and materials science, and educational labs for teaching precision weighing techniques.
    2
    How should I prepare and set up the FA series balance for accurate measurements?
    To prepare the balance: - Place it on a stable, vibration-free bench away from drafts, air-conditioning outlets, doors, or direct sunlight. - Level the balance using the built-in bubble level and adjustable feet until centered. - Allow the balance to warm up for the manufacturer-recommended time (typically 30–60 minutes) after power-on. - Keep the draft shield closed when weighing and use the same weighing container/holder consistently. - Ensure the environment (temperature, humidity) is stable; avoid placing hot or cold objects on or near the balance. - Use calibrated weights or the balance’s internal calibration routine to confirm performance before critical measurements.
    3
    How do I perform calibration and verification on the FA series analytical balance?
    Calibration steps: - Use the balance’s internal automatic calibration (if available) after warm-up and when environmental conditions change. - For external calibration, use certified calibration weights appropriate for the balance’s capacity and readability (typically class F1/M1 where applicable). - Place the calibration weight in the center of the pan or weighing chamber and follow the on-screen calibration menu. - After calibration, verify accuracy by weighing additional check weights at different points within the balance’s range. - Keep a calibration log (date, weights used, results) for audits and QC records.
    4
    What maintenance and cleaning procedures should I follow to keep the FA series balance reliable?
    Routine maintenance: - Clean spills immediately using a soft brush or lint-free cloth; for stubborn residues use a cloth lightly dampened with distilled water or a mild detergent solution, then dry thoroughly. - Never pour solvents or liquids into the balance; remove the pan and wash it separately if necessary. - Avoid cleaning the internal draft shield mechanism; consult the manual or service technician for internal cleaning. - Periodically check and tighten pan and draft shield components, and inspect for corrosion or damage. - Schedule professional preventive maintenance and recalibration annually or per facility requirements.
    5
    What should I do if the balance shows unstable or fluctuating readings?
    Troubleshooting unstable readings: - Confirm the balance is level and on a stable, vibration-free surface. - Close the draft shield and ensure no air currents (people moving, HVAC) affect the chamber. - Check for temperature fluctuations from nearby equipment, sunlight, or hot/cold samples. - Ensure sample and container are at ambient temperature before weighing to prevent convection currents. - Remove static charge from samples or containers using an antistatic brush or ionizer if available. - Verify the power supply is stable and the balance has completed warm-up; rerun calibration if needed. - If readings remain unstable after these steps, consult the manual for error codes or contact service support.
    6
    What accessories and connectivity options are available and how can I transfer data from the FA series balance?
    Accessories and data handling: - Common accessories: draft shield replacement parts, different pan sizes, weighing boats, anti-vibration tables, ionizers or static eliminators, and calibration weight sets. - Connectivity: many FA series models offer RS-232, USB, or optional Ethernet/Bluetooth interfaces for data transfer. Check the model’s specifications. - To transfer data: connect the balance to a PC or printer using the appropriate cable and interface. Use the supplied software or configure the balance to send weight data in predefined formats (e.g., stable-only capture, continuous output). - For integration into lab information systems or LIMS, confirm supported protocols and data formats; you may need middleware or the manufacturer’s software for smooth integration.
    Get in touch with us
    If you have any questions about our products or services, feel free to reach out to customer service team. We will give high quality products and best service to all our user from both homeand abroad.
    no data
    Related Products
    no data
    Customer service
    detect